Silent Knight 6700 Manual: A Comprehensive Guide

This manual details the Silent Knight 6700 fire alarm system, covering installation, programming, troubleshooting, and compatible devices like 6860/5865 annunciators and SK/SD sensors․

The Silent Knight 6700 is a versatile, addressable fire alarm control panel (FACP) designed for a wide range of applications, from small commercial buildings to large, complex facilities․ This system provides comprehensive life safety protection through advanced detection and notification capabilities․ It’s known for its reliability, ease of use, and flexible configuration options, making it a popular choice for fire protection professionals․

This manual serves as a complete guide to understanding, installing, programming, and maintaining the Silent Knight 6700 system․ It details the panel’s features, including its JumpStart auto-programming, USB interface for streamlined configuration, and drift compensation for enhanced accuracy․ Compatibility with devices like the 6860 and 5865 annunciators, alongside SK and SD sensors, expands its functionality․ Proper understanding of this manual is crucial for ensuring optimal system performance and adherence to relevant safety standards․

Understanding Fire Alarm Systems

Fire alarm systems are critical components of building safety, designed to detect and alert occupants to the presence of fire․ These systems typically consist of initiating devices (smoke detectors, heat detectors, pull stations), a control panel (like the Silent Knight 6700), notification appliances (horns, strobes), and wiring connecting these components․ The control panel receives signals from initiating devices and activates the notification appliances to evacuate the building․

Addressable systems, such as the 6700, offer significant advantages over conventional systems․ Each device has a unique address, allowing the panel to pinpoint the exact location of a fire event․ This precise information speeds up response times and minimizes unnecessary evacuations․ Understanding the core principles of fire alarm operation – detection, notification, and control – is essential for effective system management and ensuring life safety within a facility․ Regular testing and maintenance are also paramount․

Key Features of the Silent Knight 6700

The Silent Knight 6700 boasts several key features enhancing its functionality and ease of use․ JumpStart auto-programming significantly simplifies system setup, reducing programming time and potential errors․ A built-in USB interface facilitates efficient data uploading and downloading for configuration and reporting․ Furthermore, the panel incorporates advanced drift compensation, minimizing false alarms caused by environmental factors affecting sensor sensitivity․

The 6700 also features four programmable function buttons for customized control and operation․ Its compatibility with a wide range of devices, including 6860 and 5865 annunciators, the 5880 LED module, and SK/SD sensors & modules, provides flexibility in system design․ These features combine to create a robust and adaptable fire alarm control panel suitable for diverse applications and building requirements, ensuring reliable fire protection․

Technical Specifications

The Silent Knight 6700 is a sophisticated fire alarm control panel designed for reliability and performance․ It supports a maximum of 159 addressable devices, offering extensive coverage for various facility sizes․ The panel operates on a 24VDC power supply, with a standby current of 85mA and an alarm current of 165mA․ It includes a fully-sealed lead-acid battery charger, ensuring continuous operation during power outages․

Communication capabilities include an integrated printer interface and optional remote communication modules․ The 6700 features a large LCD display providing clear system status and event information․ Its enclosure is constructed from durable 16-gauge steel, meeting industry standards for physical protection․ The panel’s operating temperature range is 32°F to 120°F (0°C to 49°C), making it suitable for diverse environmental conditions․

Installation Procedures

Proper installation of the Silent Knight 6700 is crucial for reliable fire protection․ Begin by mounting the control panel enclosure securely to a wall, ensuring adequate space for wiring and access․ Connect the 24VDC power supply, observing correct polarity, and verify proper voltage levels․ Next, wire the notification appliance circuits (NACs), adhering to the specified wiring diagrams and voltage limitations․

Addressable devices are connected via a single pair of wires, simplifying installation․ Ensure proper loop wiring, avoiding shorts or opens․ After wiring, proceed with programming the panel (see section on Programming); Thoroughly test all devices and circuits after installation, verifying proper communication and alarm activation․ Always consult local codes and regulations during installation to ensure compliance and safety․

Wiring Diagrams and Connections

The Silent Knight 6700 utilizes a robust wiring scheme for reliable operation․ Notification Appliance Circuits (NACs) support both Standard and Addressable devices, requiring careful attention to wiring polarity and loop configuration․ Addressable devices connect via a single pair of wires forming a loop, simplifying installation but demanding precise termination․

Wiring diagrams, found in the full installation manual, detail specific connections for various devices, including detectors, pull stations, and remote annunciators․ Ensure all wiring conforms to National Fire Protection Association (NFPA) standards and local electrical codes․ Proper grounding is essential for minimizing interference and ensuring system stability․ Incorrect wiring can lead to false alarms or system failure, so double-check all connections before powering up the panel․

Programming the Control Panel

Programming the Silent Knight 6700 is streamlined through its intuitive interface and JumpStart auto-programming feature․ This allows for rapid device enrollment, significantly reducing setup time․ Access programming mode using the master access code, detailed in the manual․ Configuration options include zone definitions, sensitivity adjustments for detectors, and NAC programming for appropriate appliance activation․

The USB interface facilitates software updates and advanced configuration using compatible programming software․ Careful attention should be paid to cause-and-effect relationships, ensuring correct alarm and supervisory signal routing․ Regularly save programming changes to prevent data loss․ Incorrect programming can compromise system functionality, so thorough understanding of each parameter is crucial․ Refer to the comprehensive programming guide for detailed instructions and troubleshooting tips․

Compatible Devices

The Silent Knight 6700 system boasts broad compatibility, enhancing its flexibility and scalability․ Key compatible devices include the 6860 and 5865 Annunciators, providing remote system status and control․ The 5880 LED Module offers clear visual indication of alarm and trouble conditions․ A wide range of SK and SD Sensors & Modules are supported, encompassing smoke detectors, heat detectors, duct detectors, and input/output modules․

Ensure all devices are listed in the Silent Knight compatibility database for optimal performance․ Utilizing non-compatible devices may lead to system malfunctions or unreliable operation․ Proper device addressing is critical during programming, avoiding conflicts and ensuring accurate identification․ Refer to the device-specific installation manuals for detailed wiring and configuration instructions․ Regularly verify device communication to maintain system integrity․

6860 and 5865 Annunciators

The 6860 and 5865 Annunciators extend the Silent Knight 6700’s monitoring capabilities to remote locations․ These devices display system status, including alarm, trouble, and supervisory conditions, providing immediate awareness of events․ They offer a user-friendly interface for acknowledging alarms and silencing outputs․ The 6860 typically supports a larger number of zones and features more advanced programming options compared to the 5865․

Proper wiring and addressing are crucial for successful integration․ Annunciators connect to the 6700 control panel via a dedicated communication loop․ Configuration involves assigning zones to specific annunciator points, enabling clear identification of alarm locations․ Regularly test annunciator functionality to ensure reliable operation and communication with the main control panel․ Refer to the specific annunciator manual for detailed setup instructions․

5880 LED Module

The 5880 LED Module serves as a visual indicator of alarm status within the Silent Knight 6700 system․ It provides a clear, localized display of alarm, trouble, and supervisory conditions, enhancing situational awareness for building occupants and maintenance personnel․ These modules are particularly useful in areas where audible alarms may be insufficient or where a visual confirmation is desired․

Installation involves connecting the module to the system’s notification appliance circuit (NAC)․ Each LED represents a specific zone or condition, illuminating upon activation․ Proper addressing ensures accurate correlation between the LED indicator and the corresponding alarm point․ Regular testing of the 5880 module is essential to verify its functionality and ensure reliable visual signaling during emergency events․ Consult the module’s documentation for specific wiring and programming details․

SK and SD Sensors & Modules

Silent Knight (SK) and System Sensor (SD) devices are fully compatible with the 6700 control panel, offering a broad range of detection and notification options․ These include smoke detectors, heat detectors, duct detectors, pull stations, and various input/output modules․ Utilizing these devices allows for a customized fire alarm system tailored to specific building needs and hazards․

Proper device addressing is crucial for correct system operation․ Each SK/SD device must be uniquely identified within the 6700 panel’s programming․ Compatibility extends to both conventional and addressable technologies, providing flexibility during system design and upgrades․ Refer to the individual device datasheets for detailed installation instructions, wiring diagrams, and programming parameters․ Regular testing and maintenance of all SK and SD components are vital for ensuring reliable fire detection and alarm signaling․

JumpStart Auto-Programming

JumpStart is a powerful feature of the Silent Knight 6700, significantly simplifying the programming process for compatible System Sensor devices․ This automated programming method eliminates the need for manual addressing of each individual detector or module, drastically reducing installation time and potential errors․

To utilize JumpStart, ensure the control panel is in programming mode and the compatible devices are connected․ The 6700 automatically detects and programs the devices, assigning unique addresses based on their physical order of connection․ Verify the programmed device list within the panel’s interface to confirm accurate addressing․ While JumpStart streamlines programming, always double-check the configuration and perform thorough system testing to guarantee proper functionality and adherence to local fire codes․

USB Interface Functionality

The Silent Knight 6700 incorporates a USB interface, providing a convenient connection to a computer for advanced system configuration, programming, and reporting․ This interface enables users to upload and download programming files, facilitating quick system backups and efficient cloning for multiple panel installations․

Utilizing dedicated software, the USB connection allows for detailed examination of system event logs, aiding in troubleshooting and performance analysis․ Firmware updates can also be applied via the USB port, ensuring the panel operates with the latest features and security enhancements․ Proper software installation and adherence to the manufacturer’s instructions are crucial for successful USB communication and data transfer․ Regular backups via USB are highly recommended for disaster recovery purposes․

Drift Compensation Explained

Drift compensation within the Silent Knight 6700 system addresses the gradual change in sensor sensitivity over time, caused by environmental factors like dust accumulation or temperature fluctuations․ This feature automatically adjusts the alarm threshold to maintain optimal sensitivity and minimize false alarms․

The system continuously monitors sensor readings and dynamically adjusts the trigger point, ensuring reliable fire detection without unnecessary activations․ Proper configuration of drift compensation parameters is essential for effective performance․ Users can customize sensitivity levels and compensation rates based on the specific environment and application․ Regular inspection and maintenance, including sensor cleaning, complement drift compensation, ensuring long-term accuracy and system reliability․ Ignoring drift can lead to nuisance alarms or, conversely, a failure to detect a real fire․

Troubleshooting Common Issues

Common issues with the Silent Knight 6700 often involve false alarms, communication failures, or unresponsive devices․ Begin by checking the event log for specific error codes, providing valuable diagnostic information․ Verify wiring connections at all devices, ensuring secure and correct terminations․ For false alarms, investigate potential causes like dust, humidity, or nearby interference sources․

Communication problems may stem from a faulty communication bus or incorrect addressing․ If devices are unresponsive, check their power supply and programming․ Utilize the system’s built-in diagnostic tools to isolate the problem․ Remember to consult the manual’s troubleshooting section for detailed guidance and specific error code explanations․ Document all troubleshooting steps and resolutions for future reference, aiding in efficient maintenance and system upkeep․

Maintenance and Testing

Regular maintenance is crucial for ensuring the Silent Knight 6700’s reliability․ Conduct routine visual inspections of the control panel, detectors, and notification appliances for any signs of damage or obstruction․ Test all initiating devices – smoke detectors, heat detectors, and pull stations – on a scheduled basis, typically quarterly or semi-annually, as per NFPA standards․

Verify proper communication with the monitoring station during testing․ Battery backups should be tested annually to confirm they provide adequate power during outages․ Clean detectors carefully to remove dust and debris, preventing false alarms․ Document all testing and maintenance activities in a logbook, including dates, findings, and corrective actions․ Adhering to a strict maintenance schedule maximizes system performance and minimizes potential failures․

Regulatory Compliance & Standards

The Silent Knight 6700 is designed to comply with stringent fire alarm industry standards, ensuring life safety and property protection․ UL Listings and Approvals are paramount; the system typically carries UL 864 listings for control units, demonstrating adherence to rigorous testing and performance criteria․ Compliance with the National Fire Protection Association (NFPA) 72, the National Fire Alarm and Signaling Code, is essential for proper installation, maintenance, and inspection․

Local building codes and authorities having jurisdiction (AHJ) may have additional requirements․ Installation must be performed by qualified and licensed technicians․ Regular inspections by certified professionals are necessary to maintain compliance and ensure the system operates as intended․ Documentation demonstrating compliance should be readily available for AHJ review․

UL Listings and Approvals

The Silent Knight 6700 control panel boasts comprehensive UL Listings, signifying Underwriters Laboratories’ independent verification of its safety and performance․ Specifically, it typically carries the UL 864 listing for fire alarm control units, confirming it meets stringent requirements for reliability and functionality․ This listing covers aspects like alarm sensitivity, power supply stability, and communication integrity․

Furthermore, components integrated with the 6700, such as detectors and modules, should also possess relevant UL certifications․ These approvals demonstrate adherence to industry benchmarks, assuring end-users and AHJs (Authorities Having Jurisdiction) of a quality, tested system․ Maintaining these listings requires ongoing compliance with UL’s follow-up inspection program, ensuring continued adherence to safety standards․